Experimental testing of reinforced concrete walls in regions of lower seismicity

Abstract

This paper provides an overview and the results of a recent experimental study testing the lateral cyclic displacement capacity of limited ductile reinforced concrete (RC) walls. The experimental program included one monolithic cast in-situ rectangular wall specimen and one monolithic cast in-situ box-shaped building core specimen. The specimens were tested using the MAST system at Swinburne University of Technology. They were tested under cyclic in-plane unidirectional lateral load with a shear-span ratio of 6.5. The specimens were detailed to best match typical RC construction practices in regions of lower seismicity, e.g. Australia, which generally results in a ‘limited ductile’ classification to the Australian earthquake loading code. This reinforcement detailing consisted of constant-spaced horizontal and vertical bars on each face of the wall and lap splices of the vertical reinforcement at the base of the wall in the plastic hinge region. The rectangular wall and building core specimens both achieved a relatively good lateral displacement capacity given the limited ductile reinforcement detailing adopted. The lap splice at the base of the specimens resulted in a somewhat different post-yield curvature distribution being developed. Rather than a typical plastic hinge with distributed cracks being developed, a ‘two crack’ plastic hinge was formed. This consisted of one major crack at the base of the wall and another at the top of the lap splice, with only hairline cracks developing between these two major cracks. The majority of the plastic rotation was concentrated in each of these two major cracks.

References

Menegon SJ, Wilson JL, Lam NTK and Gad EF (2017). "RC Walls in Australia: Reconnaissance Survery of Industry and Literature Review of Experimental Testing". Australian Journal of Structural Engineering, 18(1): 24-40.

Standards Australia (2009). “AS 3600-2009 Concrete Structures”. SAI Global Limited, Sydney, Australia.

Standards Australia (2007). “AS 1170.4-2007 Structural Design Actions, Part 4: Earthquake Actions in Australia”. Standards Australia, Sydney.

Lestuzzi P and Bachmann H (2007). "Displacement ductility and energy assessment from shaking table tests on RC structural walls". Engineering Structures, 29(8): 1708-1721.

Dazio A, Beyer K and Bachmann H (2009). "Quasi-static cyclic tests and plastic hinge analysis of RC structural walls". Engineering Structures, 31(7): 1556-1571.

Zhang H, Lu X and Wu X (2009). "Cyclic Loading Experiment and Numerical Simulation of RC Walls". Proceedings of the 2009 World Congress on Computer Sciences and Information Engineering, Los Angeles, USA.

Hube MA, Marihuen A, Liera JCDL and Stojadinovic B (2014). "Seismic behaviour of slender reinforced concrete walls". Engineering Structures, 80: 377-388.

Alarcon C, Hube MA and Liera JCDL (2014). "Effect of axial loads in the seismic behaviour of reinforced concrete walls with unconfined wall boundaries". Engineering Structures, 73: 13-23.

Altheeb A (2016). “Seismic Drift Capacity of Lightly Reinforced Concrete Shear Walls”. PhD thesis, Department of Infrastructure Engineering, University of Melbourne, Melbourne, Australia.

Albidah A (2016). “Vulnerability and Risks of Collapse of Structural Concrete Walls in Regions of Low to Moderate Seismicity”. PhD thesis, Department of Infrastructure Engineering, University of Melbourne, Melbourne, Australia.

Lu Y (2017). “Seismic Design of Lightly Reinforced Concrete Walls”. PhD Thesis, Department of Civil and Environmental Engineering, The University of Auckland, Auckland, New Zealand.

Lu Y, Henry RS, Gultom R and Ma QT (2017). "Cyclic Testing of Reinforced Concrete Walls with Distributed Minimum Vertical Reinforcement". Journal of Structural Engineering, 143(5), DOI:10.1061/(ASCE)ST.1943-541X.0001723.

Lowes LN, Lehman DE, Birely AC, Kuchma DA, Marley KP and Hart CR (2012). "Earthquake response of slender planar concrete walls with modern detailing". Engineering Structures, 43: 31-47.

Standards Australia and Standards New Zealand (2001). “AS/NZS 4671:2001 Steel Reinforcing Materials”. Standards Australia International Ltd, Sydney and Standards New Zealand, Wellington.

Hashemi MJ, Al-Mahaidi R, Kalfat R and Burnett G (2015). "Development and validation of multi-axis substructure testing system for full-scale experiments". Australian Journal of Structural Engineering, 16(4): 302-315.

American Concrete Institute (2013). “ACI 374.2R-13 Guide for Testing Reinforced Concrete Structural Elements under Slowly Applied Simulated Seismic Loads”. American Concrete Institute, Farmington Hills, Michigan, USA.

American Concrete Institute (2008). “ACI ITG-5.1-07, Acceptance Criteria for Special Unbonded Post-Tensioned Precast Structural Walls Based on Validation Testing and Commentary”. American Concrete Institute, Farmington Hills, Michigan, USA.

Lu Y and Henry RS (2017). "Numerical modelling of reinforced concrete walls with minimum vertical reinforcement". Engineering Structures, 143: 330-345.

Hoult R, Goldsworthy H and Lumantarna E (2017). "Plastic Hinge Length for Lightly Reinforced Rectangular Concrete Walls". Journal of Earthquake Engineering, DOI:10.1080/13632469.2017.1286619 (In Press).

Published
2017-12-31
How to Cite
Menegon, S. J., Wilson, J. L., Lam, N. T., & Gad, E. F. (2017). Experimental testing of reinforced concrete walls in regions of lower seismicity. Bulletin of the New Zealand Society for Earthquake Engineering, 50(4), 494-503. https://doi.org/10.5459/bnzsee.50.4.494-503
Section
Articles